0
Model No: ZGS11-12

ZGS11-12 Box Type Transformer Substation | CANGO

CANGO supplies ZGS11-12 Combined American Prefabricated Substation for residential areas, parks, stations, and hotels. Send rated data, drawings, quantity.
Quantity :
add to cart
Contact Now
CANGO Product Detail

ZGS11-12 Box Type Transformer Substation | CANGO

Prefabricated Substations for B2B Electrical Projects
ZGS11-12 Combined American Prefabricated Substation is supplied for residential areas, parks, stations, and hotels. CANGO reviews rated data, drawings, quantity, destination, and configuration notes before quotation.
Model
ZGS11-12
Category
Prefabricated Substations
Application
Residential areas, parks, stations, and hotels
Supply Type
Project quotation and technical support

Product Overview

ZGS11-12 combined American prefabricated substation is intended for 10 kV ring network, dual power supply, or terminal power supply systems. It is commonly used for residential areas, parks, stations, and hotels and construction sites, airports, and related distribution projects, with the final selection based on rated data, drawings, and site conditions.

EPC companies, electrical contractors, utilities, developers, and overseas distributors can request configuration review for american prefabricated substation. Please send transformer capacity, HV/LV voltage combination, enclosure layout, foundation drawing, and incoming / outgoing cable scheme, quantity, destination, and any project standard requirements for quotation.

Model and Meaning

  • ZGS: American-style prefabricated substation
  • 12: rated-voltage class
  • Select the transformer rated capacity, high-voltage switchgear main-switch type, and operating-mechanism type for the ordered configuration
ZGS11-12 combined american prefabricated substation model and meaning diagram

Key Features

01

Compact Footprint

ZGS11-12: Integrated HV, transformer, and LV sections help reduce site civil work and simplify project layout planning. This point is especially relevant to american prefabricated substation.
02

Outdoor Installation

The enclosure arrangement is suitable for outdoor distribution projects when foundation, ventilation, and cable routes are confirmed. For ZGS11-12, check this together with the selected project scheme.
03

Turnkey Project Support

The configuration can be reviewed with transformer capacity, HV/LV scheme, foundation drawing, and feeder requirements. On ZGS11-12, confirm the application duty, site layout, and project standard before selection.
04

Flexible Layout

Different enclosure structures and circuit combinations can be checked according to the selected project design. Use the ZGS11-12 drawings and rated data to confirm this point before quotation.
05

Maintenance Access

Door, compartment, and cable access requirements should be confirmed before final production. For ZGS11-12, review this with american prefabricated substation and the final installation plan.

Technical Specifications

Transformer performance parameters for 10kV combined transformer S9, S10, and S11 oil-immersed series
Review the ZGS11-12 capacity, voltage combination, loss data, impedance, and selected configuration before quotation.
SerialRated capacityRated voltageVoltage adjustment rangeConnectionNo-load current (%)No-load loss (W)Load loss (W)Reference
Serial numberkVAHigh voltage (kV)Low voltage (kV)%Group numberS9S10 / S11S9S10S11S9 / S10 / S11Impedance voltage (%)Noise (dB)Temperature rise (K)
13060.4+/-5Yyn02.22.0130110100600455Top oil 55; coil 65
25060.4+/-5Yyn02.01.8170150130870455Top oil 55; coil 65
36360.4+/-5Yyn01.91.52001801501049455Top oil 55; coil 65
48060.4+/-5Yyn01.71.22502001801250455Top oil 55; coil 65
510060.4+/-5Yyn01.61.12902302001500455Top oil 55; coil 65
612560.4+/-5Yyn01.51.03402702401800455Top oil 55; coil 65
716060.4+/-5Yyn01.41.04003102802200455Top oil 55; coil 65
820060.4+/-5Yyn01.40.84803803402600455Top oil 55; coil 65
92506.30.4+/-5Yyn01.20.85604604003050455Top oil 55; coil 65
103156.30.4+/-5Yyn01.10.76705404803650455Top oil 55; coil 65
114006.30.4+/-5Yyn01.00.78006505704300455Top oil 55; coil 65
12500100.69+/-2 x 2.5Dyn111.00.69607806805150455Top oil 55; coil 65
13630100.69+/-2 x 2.5Dyn110.90.6120092081062004.555Top oil 55; coil 65
14800100.69+/-2 x 2.5Dyn110.80.61400112098075004.555Top oil 55; coil 65
151000100.69+/-2 x 2.5Dyn110.70.5170013201150103004.555Top oil 55; coil 65
161250100.69+/-2 x 2.5Dyn110.60.5195015601360120004.555Top oil 55; coil 65
171600100.69+/-2 x 2.5Dyn110.60.5240018801640145004.555Top oil 55; coil 65
Note: the high-voltage tapping range can be designed as +/-2 x 2.5% according to user requirements; the low-voltage side can be designed as 0.69kV according to user requirements.

Installation Dimensions / Drawing

ZGS11-12 combined american prefabricated substation installation dimensions drawing
ZGS11-12 Combined American Prefabricated Substation installation-dimension or outline-dimension drawing for project layout review.

Applications

ZGS11-12 is mainly selected for residential areas, parks, stations, and hotels and construction sites, airports, and related distribution projects. The final application should match the confirmed american prefabricated substation, rated data, and site installation conditions.
  • Residential areas, parks, stations, and hotels
  • Construction sites, airports, and related distribution projects
  • 10 kV ring network or terminal power supply systems

Customization Options

Transformer Options

Capacity, cooling type, connection group, tap range, and transformer room arrangement can be reviewed according to project requirements. Apply this review to ZGS11-12 and its american prefabricated substation.

HV/LV Combination

High-voltage incoming scheme, low-voltage outgoing circuits, metering, and compensation options can be selected by drawing. Apply this review to ZGS11-12 and its american prefabricated substation.

Container Structure

Enclosure layout, foundation, ventilation, doors, cable trench, and outdoor protection requirements should be confirmed before production. Apply this review to ZGS11-12 and its american prefabricated substation.

Project Finish

Color, access direction, lifting points, and special site requirements can be discussed when they are included in the inquiry. Apply this review to ZGS11-12 and its american prefabricated substation.

Transformer Options

Capacity Review

Transformer capacity, voltage combination, tap range, connection group, and cooling type should be confirmed by load requirement. Apply this review to ZGS11-12 and its american prefabricated substation.

Room Arrangement

Transformer room ventilation, access direction, lifting clearance, and maintenance space need project review. Apply this review to ZGS11-12 and its american prefabricated substation.

HV/LV Combinations

High-Voltage Side

Incoming scheme, ring network or terminal supply, metering, and protection requirements can be selected by drawing. Apply this review to ZGS11-12 and its american prefabricated substation.

Low-Voltage Side

Outgoing feeders, compensation, metering, and distribution circuits should be matched with the project load schedule. Apply this review to ZGS11-12 and its american prefabricated substation.

Container Structure

Outdoor Enclosure

The enclosure layout, foundation, doors, cable trench, ventilation, and protection level should match local site conditions. Apply this review to ZGS11-12 and its american prefabricated substation.

Project Layout

Confirm base dimensions, grounding, transport access, and installation space before final production. Apply this review to ZGS11-12 and its american prefabricated substation.

Ordering Instructions / Information Required for Quotation

ForZGS11-12, send transformer capacity, HV/LV voltage combination, enclosure layout, foundation drawing, and incoming / outgoing cable scheme, quantity, destination, and the expected delivery schedule. The engineering review will be based on the selected american prefabricated substation and project drawing.

ORDERING INSTRUCTIONS

  • Provide the operating site and any special requirements.
  • Provide ordering drawings with wiring diagrams, transformer capacity, main-component models, specifications, branch circuits, and capacity.
  • State metering and reactive-power compensation requirements when applicable.
  • State surface-treatment requirements and whether the combined transformer is terminal type or ring-network type.

Technical Support & Documentation

FAQ

What applications is ZGS11-12 used for?
ZGS11-12 is used for Residential areas, parks, stations, and hotels, Construction sites, airports, and related distribution projects, 10 kV ring network or terminal power supply systems. The final selection should match the project voltage, current, circuit arrangement, and installation conditions.
Which buyers commonly source ZGS11-12?
EPC companies, electrical contractors, utilities, developers, and overseas distributors commonly use this product for project-based electrical distribution, installation, replacement, or system expansion work.
Which rated voltage or current should be confirmed for ZGS11-12?
Confirm the rated voltage, rated current, short-circuit level, frequency, protection level, and configuration shown in the technical specifications before quotation.
CanZGS11-12 be configured for a specific project?
Yes.CANGO can review project-specific configurations according to drawings, rated data, protection requirements, component requirements, and site conditions before quotation.
Which standards should be confirmed?
Applicable standards depend on the project and destination market. State IEC, local utility, component, testing, or documentation requirements in the inquiry.
What installation information is required?
ZGS11-12 has an installation-dimension or outline-dimension image for layout review. The final drawing should still be confirmed according to the selected configuration.
What information is needed for quotation?
For quotation, send single-line diagram and substation layout drawing, rated voltage on hv side and lv side, transformer capacity, tap range, and connection group, number of high-voltage incoming / outgoing feeders, quantity, project country, delivery requirement, and any special component or environmental requirements.
How is delivery time confirmed for ZGS11-12?
Delivery time depends on the confirmed configuration, quantity, component selection, documentation requirement, and production schedule. Share the project deadline during inquiry.

Related Products

Contact / Inquiry CTA

Send project data for ZGS11-12. The fields below are the recommended information for quotation and technical review.
Use the buttons below to send the project request by email or open the contact page. If you have drawings, attach the file in the email or share a file link in the message.

Request Quotation for ZGS11-12

This is project-based power distribution equipment. Share the single-line diagram, rated data, cabinet arrangement, quantity, and destination, and CANGO will review the configuration before quotation.