0
Model No: SCBH15

SCBH15 Amorphous Alloy Dry-Type Transformer | CANGO

CANGO supplies SCBH15 Dry-Type Amorphous Alloy Iron Core Power Transformer for commercial and industrial electrical projects. Send rated data, drawings.
Quantity :
add to cart
Contact Now
CANGO Product Detail

SCBH15 Amorphous Alloy Dry-Type Transformer | CANGO

Power Transformers for B2B Electrical Projects
SCBH15 Dry-Type Amorphous Alloy Iron Core Power Transformer is supplied for commercial and industrial electrical projects. CANGO reviews rated data, drawings, quantity, destination, and configuration notes before quotation.
Model
SCBH15
Category
Power Transformers
Application
Commercial and industrial electrical projects
Supply Type
Project quotation and technical support

Product Overview

SCBH15 dry-type amorphous alloy iron core power transformer combines a dry-type transformer arrangement with an amorphous alloy core. It is commonly used for commercial and industrial electrical projects and indoor distribution systems, with the final selection based on rated data, drawings, and site conditions.

utilities, EPC contractors, transformer distributors, industrial project owners, and electrical engineering companies can request configuration review for dry type amorphous alloy transformer. Please send capacity, voltage combination, tap range, connection group, cooling or insulation type, loss data, impedance, and installation environment, quantity, destination, and any project standard requirements for quotation.

Model and Meaning

SCBH15 dry-type amorphous alloy iron core power transformer model and meaning diagram

Key Features

01

Capacity Selection

SCBH15: Capacity, high-voltage and low-voltage combination, tap range, and connection group are confirmed before quotation. This point is especially relevant to dry type amorphous alloy transformer.
02

Cooling and Insulation

Oil-immersed, dry-type, amorphous alloy, and H-class requirements are reviewed according to installation conditions. For SCBH15, check this together with the selected project scheme.
03

Loss Data Review

No-load loss, load loss, impedance, and efficiency-related data should be matched with the selected capacity. On SCBH15, confirm the application duty, site layout, and project standard before selection.
04

Project Installation

Foundation, lifting, terminal position, ventilation, and clearance requirements need confirmation before delivery. Use the SCBH15 drawings and rated data to confirm this point before quotation.
05

Application Flexibility

Transformer selection can support utility, industrial, commercial, indoor, outdoor, and renewable-energy projects. For SCBH15, review this with dry type amorphous alloy transformer and the final installation plan.

Technical Specifications

Main Product Performance Parameters of SCBH15 10 kV Amorphous Alloy Dry-Type Transformer

ModelRated capacity (kVA)Connection groupHigh voltage (kV)Tap range (%)Low voltage (kV)No-load current (%)No-load loss (W)Load loss B-class (W)Load loss F-class (W)Load loss H-class (W)Short-circuit impedance (%)
SCBH15-3030Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.41.6706707107604
SCBH15-5050Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.41.490940100010704
SCBH15-8080Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.41.31201290138014804
SCBH15-100100Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.41.21301480157016904
SCBH15-125125Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.41.11501740185019804
SCBH15-160160Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.41.11702000213022804
SCBH15-200200Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.412002370253027104
SCBH15-250250Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.412302590276029604
SCBH15-315315Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.92803270347037304
SCBH15-400400Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.83103750399042804
SCBH15-500500Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.83604590488052304
SCBH15-630630Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.74205530588062904
SCBH15-630630Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.74105610596064006
SCBH15-800800Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.74806550696074606
SCBH15-10001000Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.65507650813087606
SCBH15-12501250Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.665091009690103706
SCBH15-16001600Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.67601105011730125806
SCBH15-20002000Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.510001360014450155606
SCBH15-25002500Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.512001615017170184506
SCBH15-16001600Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.67601228012960139008
SCBH15-20002000Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.510001502015960171108
SCBH15-25002500Dyn11 / Yyn06 / 6.3 / 6.6 / 10 / 10.5 / 11+/-2.5% / +/-5%; selected capacities +/-2 x 2.5% / +/-5%0.40.512001776018890202908

Installation Dimensions / Drawing

ForSCBH15, confirm the capacity-specific outline dimensions, installation base, terminal position, cooling clearance, and lifting / handling requirements. Use the confirmed technical table, project drawing, and site installation plan as the final dimensional reference before ordering or installation.

Applications

SCBH15 is mainly selected for commercial and industrial electrical projects and indoor distribution systems. The final application should match the confirmed dry type amorphous alloy transformer, rated data, and site installation conditions.
  • Commercial and industrial electrical projects
  • Indoor distribution systems
  • Projects requiring dry-type amorphous alloy core transformers

Customization Options

Cooling Method

Oil-immersed, dry-type, natural cooling, forced-air, or special cooling requirements should be confirmed by model and site condition. Apply this review to SCBH15 and its dry type amorphous alloy transformer.

Winding Material

Copper or aluminum winding requirements should be confirmed when the project specification requires a fixed material. Apply this review to SCBH15 and its dry type amorphous alloy transformer.

Loss Data

No-load loss, load loss, impedance voltage, and efficiency information should be checked against the selected capacity. Apply this review to SCBH15 and its dry type amorphous alloy transformer.

Installation Method

Indoor, outdoor, foundation, ventilation, lifting, terminal position, and clearance requirements should be provided before quotation. Apply this review to SCBH15 and its dry type amorphous alloy transformer.

Cooling Method and Winding Material

Cooling Review

Confirm oil-immersed, dry-type, natural cooling, forced-air, or other cooling requirements according to the installation site. Apply this review to SCBH15 and its dry type amorphous alloy transformer.

Winding Requirement

State copper or aluminum winding requirements when the project specification defines the material. Apply this review to SCBH15 and its dry type amorphous alloy transformer.

Loss Data and Efficiency Information

Performance Data

No-load loss, load loss, impedance, noise, and temperature rise should be reviewed for the selected capacity. Apply this review to SCBH15 and its dry type amorphous alloy transformer.

Efficiency Review

Energy-efficiency level or local efficiency requirements should be confirmed before quotation if required by the project. Apply this review to SCBH15 and its dry type amorphous alloy transformer.

Ordering Instructions / Information Required for Quotation

ForSCBH15, send capacity, voltage combination, tap range, connection group, cooling or insulation type, loss data, impedance, and installation environment, quantity, destination, and the expected delivery schedule. The engineering review will be based on the selected dry type amorphous alloy transformer and project drawing.

ORDERING INSTRUCTIONS

  • State the required SCBH15 configuration, quantity, project destination, and intended application.
  • Provide capacity, voltage combination, tap range, connection group, impedance, loss data, cooling or insulation type, and installation environment for technical review.
  • Confirm confirm the capacity-specific outline dimensions, installation base, terminal position, cooling clearance, and lifting / handling requirements before final production or installation planning.
  • List any special environmental, wiring, communication, metering, protection, or component requirements in the inquiry.

Technical Support & Documentation

FAQ

What applications is SCBH15 used for?
SCBH15 is used for Commercial and industrial electrical projects, Indoor distribution systems, Projects requiring dry-type amorphous alloy core transformers. The final selection should match the project voltage, current, circuit arrangement, and installation conditions.
Which buyers commonly source SCBH15?
utilities, EPC contractors, transformer distributors, industrial project owners, and electrical engineering companies commonly use this product for project-based electrical distribution, installation, replacement, or system expansion work.
Which rated voltage or current should be confirmed for SCBH15?
Confirm the rated voltage, rated current, short-circuit level, frequency, protection level, and configuration shown in the technical specifications before quotation.
CanSCBH15 be configured for a specific project?
Yes.CANGO can review project-specific configurations according to drawings, rated data, protection requirements, component requirements, and site conditions before quotation.
Which standards should be confirmed?
Applicable standards depend on the project and destination market. State IEC, local utility, component, testing, or documentation requirements in the inquiry.
What installation information is required?
SCBH15 should be matched with the final project drawing and outline data before installation. Send the cabinet scheme or layout requirement for review.
What information is needed for quotation?
For quotation, send transformer type and required capacity, high-voltage and low-voltage rated voltage, frequency, phase, tap range, and connection group, cooling method, insulation type, and winding material requirement, quantity, project country, delivery requirement, and any special component or environmental requirements.
How is delivery time confirmed for SCBH15?
Delivery time depends on the confirmed configuration, quantity, component selection, documentation requirement, and production schedule. Share the project deadline during inquiry.

Related Products

Contact / Inquiry CTA

Send project data for SCBH15. The fields below are the recommended information for quotation and technical review.
Use the buttons below to send the project request by email or open the contact page. If you have drawings, attach the file in the email or share a file link in the message.

Request Quotation for SCBH15

This is project-based power distribution equipment. Share the single-line diagram, rated data, cabinet arrangement, quantity, and destination, and CANGO will review the configuration before quotation.