0
Model No: SRM-12

SRM-12 12kV Gas-Insulated RMU | CANGO

CANGO supplies SRM-12 12kV Gas-Insulated RMU for urban and rural distribution systems. Send rated data, drawings, quantity, and destination for quotation.
Quantity :
add to cart
Contact Now
CANGO Product Detail

SRM-12 12kV Gas-Insulated RMU | CANGO

Medium-Voltage Switchgear for B2B Electrical Projects
SRM-12 12kV Gas-Insulated RMU is supplied for urban and rural distribution systems. CANGO reviews rated data, drawings, quantity, destination, and configuration notes before quotation.
Model
SRM-12
Category
Medium-Voltage Switchgear
Application
Urban and rural distribution systems
Supply Type
Project quotation and technical support

Product Overview

SRM-12 is a 12kV gas-insulated RMU for 6kV and 10kV medium-voltage distribution systems. It is commonly used for urban and rural distribution systems and compact substations, with the final selection based on rated data, drawings, and site conditions.

EPC companies, electrical contractors, utility project teams, panel builders, and industrial buyers can request configuration review for sealed modular RMU configuration. Please send single-line diagram, rated voltage, rated current, short-circuit level, protection scheme, busbar arrangement, and cabinet layout, quantity, destination, and any project standard requirements for quotation.

Key Features

01

Safe Switching

SRM-12: The cabinet scheme can be reviewed for rated voltage, rated current, short-circuit level, interlocking, and protection requirements. This point is especially relevant to sealed modular RMU configuration.
02

Flexible Configuration

Incoming, outgoing, metering, busbar, and protection arrangements can be matched to the project single-line diagram. For SRM-12, check this together with the selected project scheme.
03

Utility Project Fit

The equipment is suitable for distribution rooms, substations, cable networks, and infrastructure power systems. On SRM-12, confirm the application duty, site layout, and project standard before selection.
04

Drawing-Based Selection

Cabinet width, depth, cable trench, busbar interface, and foundation details should be confirmed from project drawings. Use the SRM-12 drawings and rated data to confirm this point before quotation.
05

Maintenance Planning

Access, isolation, grounding, and operation sequence requirements can be reviewed before quotation. For SRM-12, review this with sealed modular RMU configuration and the final installation plan.

Technical Specifications

SRM-12 Technical Parameter Table
Review the SRM-12 module arrangement, rated data, and selected configuration before quotation.
ItemUnitC moduleF moduleV moduleCB module
Load switchGISVacuum switchIsolation / grounding switchCircuit breaker vacuum breakIsolation / grounding switch
Rated voltagekV121212121212
Rated frequencyHz505050505050
Power-frequency withstand voltage, phase to phase / portkV42 / 4842 / 4842 / 4842 / 4842 / 4842 / 48
Lightning impulse withstand voltagekV75 / 8575 / 8575 / 8575 / 8575 / 8575 / 85
Rated currentA630Note 16301250 / 630
Rated closed-loop breaking currentA630
Rated current charging interruption currentA135 / 135
Rated short-circuit closing current, peakA5080
Rated peak withstand currentkA50
Rated short-time withstand currentkA / 3 s20
Rated short-circuit breaking currentkA31.52025
Rated transfer currentA1750
Maximum current of equipped fuseA-125
Loop resistancemicro-ohm<= 300<= 600
Mechanical life span, number of timestime500030005000200050005000
Note 1: It depends on the rated current of the fuse.

Installation Dimensions / Drawing

SRM-12 gas-insulated ring main unit cabinet arrangement drawing
SRM-12 cabinet arrangement drawing showing module front views for ring main unit configuration review.

Applications

SRM-12 is mainly selected for urban and rural distribution systems and compact substations. The final application should match the confirmed sealed modular RMU configuration, rated data, and site installation conditions.
  • Urban and rural distribution systems
  • Compact substations
  • Cable network and project distribution rooms

Customization Options

Protection Options

Relay protection, metering, interlocking, grounding, and auxiliary circuit requirements can be reviewed by single-line diagram. Apply this review to SRM-12 and its sealed modular RMU configuration.

Busbar Configuration

Single busbar, sectional busbar, incoming, outgoing, metering, and bus-tie arrangements should be confirmed before quotation. Apply this review to SRM-12 and its sealed modular RMU configuration.

Cable Interface

Cable entry, cable trench, termination space, and grounding arrangement can be checked with the cabinet layout drawing. Apply this review to SRM-12 and its sealed modular RMU configuration.

Operation Scheme

Fixed, removable, ring-main, GIS, or modular arrangements are selected according to the project network design. Apply this review to SRM-12 and its sealed modular RMU configuration.

Single Line Diagram

Drawing Input

Provide the project single-line diagram so incoming, outgoing, metering, bus-tie, and protection functions can be reviewed. Apply this review to SRM-12 and its sealed modular RMU configuration.

Scheme Review

Rated voltage, rated current, short-circuit level, operating sequence, and cabinet quantity should match the final network design. Apply this review to SRM-12 and its sealed modular RMU configuration.

Protection Options

Relay and Metering

Protection relay, metering, auxiliary circuit, and communication requirements can be selected according to the project specification. Apply this review to SRM-12 and its sealed modular RMU configuration.

Safety Interlocking

Interlocking, grounding, isolation, and operation sequence requirements should be confirmed before final cabinet design. Apply this review to SRM-12 and its sealed modular RMU configuration.

Busbar Configuration

Busbar Arrangement

Single busbar, sectional busbar, bus coupler, and incoming / outgoing cabinet order can be checked from the layout. Apply this review to SRM-12 and its sealed modular RMU configuration.

Interface Review

Busbar current, cable trench, cabinet depth, and connection interface should be confirmed before production. Apply this review to SRM-12 and its sealed modular RMU configuration.

Ordering Instructions / Information Required for Quotation

ForSRM-12, send single-line diagram, rated voltage, rated current, short-circuit level, protection scheme, busbar arrangement, and cabinet layout, quantity, destination, and the expected delivery schedule. The engineering review will be based on the selected sealed modular RMU configuration and project drawing.

ORDERING INSTRUCTIONS

  • State the required SRM-12 configuration, quantity, project destination, and intended application.
  • Provide single-line diagram, rated voltage, rated current, short-circuit level, cabinet quantity, component configuration, and protection requirements for technical review.
  • Confirm confirm the final cabinet outline, foundation channel, cable trench, busbar interface, and cabinet arrangement drawing before final production or installation planning.
  • List any special environmental, wiring, communication, metering, protection, or component requirements in the inquiry.

Technical Support & Documentation

FAQ

What applications is SRM-12 used for?
SRM-12 is used for Urban and rural distribution systems, Compact substations, Cable network and project distribution rooms. The final selection should match the project voltage, current, circuit arrangement, and installation conditions.
Which buyers commonly source SRM-12?
EPC companies, electrical contractors, utility project teams, panel builders, and industrial buyers commonly use this product for project-based electrical distribution, installation, replacement, or system expansion work.
Which rated voltage or current should be confirmed for SRM-12?
Confirm the rated voltage, rated current, short-circuit level, frequency, protection level, and configuration shown in the technical specifications before quotation.
CanSRM-12 be configured for a specific project?
Yes.CANGO can review project-specific configurations according to drawings, rated data, protection requirements, component requirements, and site conditions before quotation.
Which standards should be confirmed?
Applicable standards depend on the project and destination market. State IEC, local utility, component, testing, or documentation requirements in the inquiry.
What installation information is required?
SRM-12 should be matched with the final project drawing and outline data before installation. Send the cabinet scheme or layout requirement for review.
What information is needed for quotation?
For quotation, send single-line diagram, rated voltage and rated current, short-circuit level, number of incoming and outgoing feeders, quantity, project country, delivery requirement, and any special component or environmental requirements.
How is delivery time confirmed for SRM-12?
Delivery time depends on the confirmed configuration, quantity, component selection, documentation requirement, and production schedule. Share the project deadline during inquiry.

Related Products

Contact / Inquiry CTA

Send project data for SRM-12. The fields below are the recommended information for quotation and technical review.
Use the buttons below to send the project request by email or open the contact page. If you have drawings, attach the file in the email or share a file link in the message.

Request Quotation for SRM-12

This is project-based power distribution equipment. Share the single-line diagram, rated data, cabinet arrangement, quantity, and destination, and CANGO will review the configuration before quotation.