Subscribe to our Newsletter
Model No: SRM-12
SRM-12 12kV Gas-Insulated RMU | CANGO
CANGO supplies SRM-12 12kV Gas-Insulated RMU for urban and rural distribution systems. Send rated data, drawings, quantity, and destination for quotation.
Quantity :
CANGO Product Detail
SRM-12 12kV Gas-Insulated RMU | CANGO
Medium-Voltage Switchgear for B2B Electrical Projects
SRM-12 12kV Gas-Insulated RMU is supplied for urban and rural distribution systems. CANGO reviews rated data, drawings, quantity, destination, and configuration notes before quotation.
Model
SRM-12
Category
Medium-Voltage Switchgear
Application
Urban and rural distribution systems
Supply Type
Project quotation and technical support
Product Overview
SRM-12 is a 12kV gas-insulated RMU for 6kV and 10kV medium-voltage distribution systems. It is commonly used for urban and rural distribution systems and compact substations, with the final selection based on rated data, drawings, and site conditions.
EPC companies, electrical contractors, utility project teams, panel builders, and industrial buyers can request configuration review for sealed modular RMU configuration. Please send single-line diagram, rated voltage, rated current, short-circuit level, protection scheme, busbar arrangement, and cabinet layout, quantity, destination, and any project standard requirements for quotation.
Key Features
01
Safe Switching
SRM-12: The cabinet scheme can be reviewed for rated voltage, rated current, short-circuit level, interlocking, and protection requirements. This point is especially relevant to sealed modular RMU configuration.
02
Flexible Configuration
Incoming, outgoing, metering, busbar, and protection arrangements can be matched to the project single-line diagram. For SRM-12, check this together with the selected project scheme.
03
Utility Project Fit
The equipment is suitable for distribution rooms, substations, cable networks, and infrastructure power systems. On SRM-12, confirm the application duty, site layout, and project standard before selection.
04
Drawing-Based Selection
Cabinet width, depth, cable trench, busbar interface, and foundation details should be confirmed from project drawings. Use the SRM-12 drawings and rated data to confirm this point before quotation.
05
Maintenance Planning
Access, isolation, grounding, and operation sequence requirements can be reviewed before quotation. For SRM-12, review this with sealed modular RMU configuration and the final installation plan.
Technical Specifications
SRM-12 Technical Parameter Table
Review the SRM-12 module arrangement, rated data, and selected configuration before quotation.
| Item | Unit | C module | F module | V module | CB module | ||
|---|---|---|---|---|---|---|---|
| Load switch | GIS | Vacuum switch | Isolation / grounding switch | Circuit breaker vacuum break | Isolation / grounding switch | ||
| Rated voltage | kV | 12 | 12 | 12 | 12 | 12 | 12 |
| Rated frequency | Hz | 50 | 50 | 50 | 50 | 50 | 50 |
| Power-frequency withstand voltage, phase to phase / port | kV | 42 / 48 | 42 / 48 | 42 / 48 | 42 / 48 | 42 / 48 | 42 / 48 |
| Lightning impulse withstand voltage | kV | 75 / 85 | 75 / 85 | 75 / 85 | 75 / 85 | 75 / 85 | 75 / 85 |
| Rated current | A | 630 | Note 1 | 630 | 1250 / 630 | ||
| Rated closed-loop breaking current | A | 630 | |||||
| Rated current charging interruption current | A | 135 / 135 | |||||
| Rated short-circuit closing current, peak | A | 50 | 80 | ||||
| Rated peak withstand current | kA | 50 | |||||
| Rated short-time withstand current | kA / 3 s | 20 | |||||
| Rated short-circuit breaking current | kA | 31.5 | 20 | 25 | |||
| Rated transfer current | A | 1750 | |||||
| Maximum current of equipped fuse | A | - | 125 | ||||
| Loop resistance | micro-ohm | <= 300 | <= 600 | ||||
| Mechanical life span, number of times | time | 5000 | 3000 | 5000 | 2000 | 5000 | 5000 |
Note 1: It depends on the rated current of the fuse.
Installation Dimensions / Drawing
Applications
SRM-12 is mainly selected for urban and rural distribution systems and compact substations. The final application should match the confirmed sealed modular RMU configuration, rated data, and site installation conditions.
- Urban and rural distribution systems
- Compact substations
- Cable network and project distribution rooms
Customization Options
Protection Options
Relay protection, metering, interlocking, grounding, and auxiliary circuit requirements can be reviewed by single-line diagram. Apply this review to SRM-12 and its sealed modular RMU configuration.
Busbar Configuration
Single busbar, sectional busbar, incoming, outgoing, metering, and bus-tie arrangements should be confirmed before quotation. Apply this review to SRM-12 and its sealed modular RMU configuration.
Cable Interface
Cable entry, cable trench, termination space, and grounding arrangement can be checked with the cabinet layout drawing. Apply this review to SRM-12 and its sealed modular RMU configuration.
Operation Scheme
Fixed, removable, ring-main, GIS, or modular arrangements are selected according to the project network design. Apply this review to SRM-12 and its sealed modular RMU configuration.
Single Line Diagram
Drawing Input
Provide the project single-line diagram so incoming, outgoing, metering, bus-tie, and protection functions can be reviewed. Apply this review to SRM-12 and its sealed modular RMU configuration.
Scheme Review
Rated voltage, rated current, short-circuit level, operating sequence, and cabinet quantity should match the final network design. Apply this review to SRM-12 and its sealed modular RMU configuration.
Protection Options
Relay and Metering
Protection relay, metering, auxiliary circuit, and communication requirements can be selected according to the project specification. Apply this review to SRM-12 and its sealed modular RMU configuration.
Safety Interlocking
Interlocking, grounding, isolation, and operation sequence requirements should be confirmed before final cabinet design. Apply this review to SRM-12 and its sealed modular RMU configuration.
Busbar Configuration
Busbar Arrangement
Single busbar, sectional busbar, bus coupler, and incoming / outgoing cabinet order can be checked from the layout. Apply this review to SRM-12 and its sealed modular RMU configuration.
Interface Review
Busbar current, cable trench, cabinet depth, and connection interface should be confirmed before production. Apply this review to SRM-12 and its sealed modular RMU configuration.
Ordering Instructions / Information Required for Quotation
ForSRM-12, send single-line diagram, rated voltage, rated current, short-circuit level, protection scheme, busbar arrangement, and cabinet layout, quantity, destination, and the expected delivery schedule. The engineering review will be based on the selected sealed modular RMU configuration and project drawing.
ORDERING INSTRUCTIONS
- State the required SRM-12 configuration, quantity, project destination, and intended application.
- Provide single-line diagram, rated voltage, rated current, short-circuit level, cabinet quantity, component configuration, and protection requirements for technical review.
- Confirm confirm the final cabinet outline, foundation channel, cable trench, busbar interface, and cabinet arrangement drawing before final production or installation planning.
- List any special environmental, wiring, communication, metering, protection, or component requirements in the inquiry.
Technical Support & Documentation
Series Technical DocumentRequest the series technical document for 12kV ring main unit and compare SRM-12 with related models and confirmed technical data.Project Technical SupportSend project data for gas insulated switchgear manufacturer so CANGO can review rated values, configuration notes, and application conditions.Send Single Line DiagramShare the single-line diagram or layout when checking RMU switchgear supplier for the selected SRM-12configuration.Engineering ConsultationDiscuss site conditions, documentation needs, and quotation details for compact medium voltage RMU.
FAQ
Related Products
GTXGN-12 Solid-Insulated Ring Main UnitGTXGN-12 Solid-Insulated Ring Main Unit for cable ring networks and distribution terminals.KYN61-40.5 Armored Removable AC Metal-Enclosed SwitchgearKYN61-40.5 Armored Removable AC Metal-Enclosed Switchgear for power plants and substations.XGN17-40.5 Box-Type Fixed AC Metal-Enclosed SwitchgearXGN17-40.5 Box-Type Fixed AC Metal-Enclosed Switchgear for medium-voltage electrical distribution systems.KYN28-24 Armored Removable AC Metal-Enclosed SwitchgearKYN28-24 Armored Removable AC Metal-Enclosed Switchgear for medium-voltage power distribution systems.
Contact / Inquiry CTA
Send project data for SRM-12. The fields below are the recommended information for quotation and technical review.
Use the buttons below to send the project request by email or open the contact page. If you have drawings, attach the file in the email or share a file link in the message.
Request Quotation for SRM-12
This is project-based power distribution equipment. Share the single-line diagram, rated data, cabinet arrangement, quantity, and destination, and CANGO will review the configuration before quotation.