CANGO supplies XGN17-40.5 Box-Type Fixed AC Metal-Enclosed Switchgear for medium-voltage electrical distribution systems. Send rated data, drawings.
Quantity :
add to cart
Contact Now
CANGO Product Detail
XGN17-40.5 40.5kV Fixed Switchgear | CANGO
Medium-Voltage Switchgear for B2B Electrical Projects
XGN17-40.5 Box-Type Fixed AC Metal-Enclosed Switchgear is supplied for medium-voltage electrical distribution systems. CANGO reviews rated data, drawings, quantity, destination, and configuration notes before quotation.
XGN17-40.5 box-type fixed AC metal-enclosed switchgear is designed for medium-voltage distribution projects that require a fixed metal-enclosed cabinet arrangement. It is commonly used for medium-voltage electrical distribution systems and industrial and project distribution rooms, with the final selection based on rated data, drawings, and site conditions.
EPC companies, electrical contractors, utility project teams, panel builders, and industrial buyers can request configuration review for fixed metal enclosed switchgear. Please send single-line diagram, rated voltage, rated current, short-circuit level, protection scheme, busbar arrangement, and cabinet layout, quantity, destination, and any project standard requirements for quotation.
Model and Meaning
XGN: indoor fixed box-type AC metal-enclosed switchgear
17: design serial number
40.5: rated voltage
Confirm rated current, short-circuit breaking current, and scheme number
Key Features
01
Safe Switching
XGN17-40.5: The cabinet scheme can be reviewed for rated voltage, rated current, short-circuit level, interlocking, and protection requirements. This point is especially relevant to fixed metal enclosed switchgear.
02
Flexible Configuration
Incoming, outgoing, metering, busbar, and protection arrangements can be matched to the project single-line diagram. For XGN17-40.5, check this together with the selected project scheme.
03
Utility Project Fit
The equipment is suitable for distribution rooms, substations, cable networks, and infrastructure power systems. On XGN17-40.5, confirm the application duty, site layout, and project standard before selection.
04
Drawing-Based Selection
Cabinet width, depth, cable trench, busbar interface, and foundation details should be confirmed from project drawings. Use the XGN17-40.5 drawings and rated data to confirm this point before quotation.
05
Maintenance Planning
Access, isolation, grounding, and operation sequence requirements can be reviewed before quotation. For XGN17-40.5, review this with fixed metal enclosed switchgear and the final installation plan.
Technical Specifications
XGN17-40.5 Technical Parameter Table
Review the XGN17-40.5 rated data, selected configuration, and project requirements before quotation.
Group
Item
Unit
Parameter
Rated voltage
kV
40.5
Maximum rated current
A
2000
Rated breaking current
kA
25 / 31.5
Rated closing current, peak value
kA
63 / 80
Limiting through-current peak value
kA
63 / 80
Rated short-time withstand current
kA
31.5 / 4 s
Outline dimensions
mm
1918 x 3250 x 3125
Enclosure protection level
IP2X
Approximate weight
kg
1500
Installation Dimensions / Drawing
XGN17-40.5 structural dimension drawing with cabinet outline, component positions, and basic dimension references for layout review.
Applications
XGN17-40.5 is mainly selected for medium-voltage electrical distribution systems and industrial and project distribution rooms. The final application should match the confirmed fixed metal enclosed switchgear, rated data, and site installation conditions.
Relay protection, metering, interlocking, grounding, and auxiliary circuit requirements can be reviewed by single-line diagram. Apply this review to XGN17-40.5 and its fixed metal enclosed switchgear.
Busbar Configuration
Single busbar, sectional busbar, incoming, outgoing, metering, and bus-tie arrangements should be confirmed before quotation. Apply this review to XGN17-40.5 and its fixed metal enclosed switchgear.
Cable Interface
Cable entry, cable trench, termination space, and grounding arrangement can be checked with the cabinet layout drawing. Apply this review to XGN17-40.5 and its fixed metal enclosed switchgear.
Operation Scheme
Fixed, removable, ring-main, GIS, or modular arrangements are selected according to the project network design. Apply this review to XGN17-40.5 and its fixed metal enclosed switchgear.
Single Line Diagram
Drawing Input
Provide the project single-line diagram so incoming, outgoing, metering, bus-tie, and protection functions can be reviewed. Apply this review to XGN17-40.5 and its fixed metal enclosed switchgear.
Scheme Review
Rated voltage, rated current, short-circuit level, operating sequence, and cabinet quantity should match the final network design. Apply this review to XGN17-40.5 and its fixed metal enclosed switchgear.
Protection Options
Relay and Metering
Protection relay, metering, auxiliary circuit, and communication requirements can be selected according to the project specification. Apply this review to XGN17-40.5 and its fixed metal enclosed switchgear.
Safety Interlocking
Interlocking, grounding, isolation, and operation sequence requirements should be confirmed before final cabinet design. Apply this review to XGN17-40.5 and its fixed metal enclosed switchgear.
Busbar Configuration
Busbar Arrangement
Single busbar, sectional busbar, bus coupler, and incoming / outgoing cabinet order can be checked from the layout. Apply this review to XGN17-40.5 and its fixed metal enclosed switchgear.
Interface Review
Busbar current, cable trench, cabinet depth, and connection interface should be confirmed before production. Apply this review to XGN17-40.5 and its fixed metal enclosed switchgear.
Ordering Instructions / Information Required for Quotation
ForXGN17-40.5, send single-line diagram, rated voltage, rated current, short-circuit level, protection scheme, busbar arrangement, and cabinet layout, quantity, destination, and the expected delivery schedule. The engineering review will be based on the selected fixed metal enclosed switchgear and project drawing.
ORDERING INSTRUCTIONS
Provide the primary-line number, primary-system diagram, and rated current.
Provide the secondary-line schematic and high-voltage cabinet layout.
State any non-standard primary solution, busbar specification, and switch-cabinet paint color.
XGN17-40.5 is used for Medium-voltage electrical distribution systems, Industrial and project distribution rooms, Projects requiring fixed metal-enclosed switchgear. The final selection should match the project voltage, current, circuit arrangement, and installation conditions.
Which buyers commonly source XGN17-40.5?
EPC companies, electrical contractors, utility project teams, panel builders, and industrial buyers commonly use this product for project-based electrical distribution, installation, replacement, or system expansion work.
Which rated voltage or current should be confirmed for XGN17-40.5?
Confirm the rated voltage, rated current, short-circuit level, frequency, protection level, and configuration shown in the technical specifications before quotation.
CanXGN17-40.5 be configured for a specific project?
Yes.CANGO can review project-specific configurations according to drawings, rated data, protection requirements, component requirements, and site conditions before quotation.
Which standards should be confirmed?
Applicable standards depend on the project and destination market. State IEC, local utility, component, testing, or documentation requirements in the inquiry.
What installation information is required?
XGN17-40.5 should be matched with the final project drawing and outline data before installation. Send the cabinet scheme or layout requirement for review.
What information is needed for quotation?
For quotation, send single-line diagram, rated voltage and rated current, short-circuit level, number of incoming and outgoing feeders, quantity, project country, delivery requirement, and any special component or environmental requirements.
How is delivery time confirmed for XGN17-40.5?
Delivery time depends on the confirmed configuration, quantity, component selection, documentation requirement, and production schedule. Share the project deadline during inquiry.
Send project data for XGN17-40.5. The fields below are the recommended information for quotation and technical review.
Use the buttons below to send the project request by email or open the contact page. If you have drawings, attach the file in the email or share a file link in the message.
This is project-based power distribution equipment. Share the single-line diagram, rated data, cabinet arrangement, quantity, and destination, and CANGO will review the configuration before quotation.