Subscribe to our Newsletter
Model No: SH15-M
SH15-M Amorphous Alloy Transformer | CANGO
CANGO supplies SH15-M sealed amorphous alloy power transformer for electrical distribution projects. Review product details and request quotation support.
Quantity :
CANGO Product Detail
SH15-M Amorphous Alloy Transformer | CANGO
Power Transformers for B2B Electrical Projects
SH15-M Sealed Amorphous Alloy Power Transformer is supplied for outdoor power distribution systems. CANGO reviews rated data, drawings, quantity, destination, and configuration notes before quotation.
Model
SH15-M
Category
Power Transformers
Application
Outdoor power distribution systems
Supply Type
Project quotation and technical support
Product Overview
SH15-M sealed amorphous alloy power transformer is used for voltage conversion and energy distribution. It is commonly used for outdoor power distribution systems and urban and rural distribution networks, with the final selection based on rated data, drawings, and site conditions.
utilities, EPC contractors, transformer distributors, industrial project owners, and electrical engineering companies can request configuration review for amorphous alloy transformer. Please send capacity, voltage combination, tap range, connection group, cooling or insulation type, loss data, impedance, and installation environment, quantity, destination, and any project standard requirements for quotation.
Model and Meaning

Key Features
01
Capacity Selection
SH15-M: Capacity, high-voltage and low-voltage combination, tap range, and connection group are confirmed before quotation. This point is especially relevant to amorphous alloy transformer.
02
Cooling and Insulation
Oil-immersed, dry-type, amorphous alloy, and H-class requirements are reviewed according to installation conditions. For SH15-M, check this together with the selected project scheme.
03
Loss Data Review
No-load loss, load loss, impedance, and efficiency-related data should be matched with the selected capacity. On SH15-M, confirm the application duty, site layout, and project standard before selection.
04
Project Installation
Foundation, lifting, terminal position, ventilation, and clearance requirements need confirmation before delivery. Use the SH15-M drawings and rated data to confirm this point before quotation.
05
Application Flexibility
Transformer selection can support utility, industrial, commercial, indoor, outdoor, and renewable-energy projects. For SH15-M, review this with amorphous alloy transformer and the final installation plan.
Technical Specifications
Product Performance Parameters of SH15-M Sealed Amorphous Alloy Power Transformer
| Rated capacity (kVA) | High voltage (kV) | Tap range (%) | Low voltage (kV) | Connection group | No-load loss (W) | Yy load loss (W) | Dy load loss (W) | Short-circuit impedance (%) | No-load current (%) |
|---|---|---|---|---|---|---|---|---|---|
| 30 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 33 | 600 | 630 | 4 | 1.5 |
| 50 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 43 | 870 | 910 | 4 | 1.2 |
| 63 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 50 | 1040 | 1090 | 4 | 1.1 |
| 80 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 60 | 1250 | 1310 | 4 | 1 |
| 100 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 75 | 1500 | 1580 | 4 | 0.9 |
| 125 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 85 | 1800 | 1890 | 4 | 0.8 |
| 160 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 100 | 2200 | 2310 | 4 | 0.6 |
| 200 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 120 | 2600 | 2730 | 4 | 0.6 |
| 250 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 140 | 3050 | 3200 | 4 | 0.6 |
| 315 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 170 | 3650 | 3830 | 4 | 0.5 |
| 400 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 200 | 4300 | 4520 | 4 | 0.5 |
| 500 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 240 | 5150 | 5410 | 4 | 0.5 |
| 630 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 320 | 6200 | 6200 | 4.5 | 0.3 |
| 800 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 380 | 7500 | 7500 | 4.5 | 0.3 |
| 1000 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 450 | 10300 | 10300 | 4.5 | 0.3 |
| 1250 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 530 | 12000 | 12000 | 4.5 | 0.2 |
| 1600 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 630 | 14500 | 14500 | 4.5 | 0.2 |
| 2000 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 750 | 18300 | 18300 | 5 | 0.2 |
| 2500 | 6 / 6.3 / 10 / 10.5 / 11 | +/-5% or +/-2 x 2.5% | 0.4 | Yyn0 or Dyn11 | 900 | 21200 | 21200 | 5 | 0.2 |
When a three-phase three-column core is used, the Yyn0 connection group can also be selected as required.
Installation Dimensions / Drawing
ForSH15-M, confirm the capacity-specific outline dimensions, installation base, terminal position, cooling clearance, and lifting / handling requirements. Use the confirmed technical table, project drawing, and site installation plan as the final dimensional reference before ordering or installation.
Applications
SH15-M is mainly selected for outdoor power distribution systems and urban and rural distribution networks. The final application should match the confirmed amorphous alloy transformer, rated data, and site installation conditions.
- Outdoor power distribution systems
- Urban and rural distribution networks
- Projects requiring sealed amorphous alloy transformers
Customization Options
Cooling Method
Oil-immersed, dry-type, natural cooling, forced-air, or special cooling requirements should be confirmed by model and site condition. Apply this review to SH15-M and its amorphous alloy transformer.
Winding Material
Copper or aluminum winding requirements should be confirmed when the project specification requires a fixed material. Apply this review to SH15-M and its amorphous alloy transformer.
Loss Data
No-load loss, load loss, impedance voltage, and efficiency information should be checked against the selected capacity. Apply this review to SH15-M and its amorphous alloy transformer.
Installation Method
Indoor, outdoor, foundation, ventilation, lifting, terminal position, and clearance requirements should be provided before quotation. Apply this review to SH15-M and its amorphous alloy transformer.
Cooling Method and Winding Material
Cooling Review
Confirm oil-immersed, dry-type, natural cooling, forced-air, or other cooling requirements according to the installation site. Apply this review to SH15-M and its amorphous alloy transformer.
Winding Requirement
State copper or aluminum winding requirements when the project specification defines the material. Apply this review to SH15-M and its amorphous alloy transformer.
Loss Data and Efficiency Information
Performance Data
No-load loss, load loss, impedance, noise, and temperature rise should be reviewed for the selected capacity. Apply this review to SH15-M and its amorphous alloy transformer.
Efficiency Review
Energy-efficiency level or local efficiency requirements should be confirmed before quotation if required by the project. Apply this review to SH15-M and its amorphous alloy transformer.
Ordering Instructions / Information Required for Quotation
ForSH15-M, send capacity, voltage combination, tap range, connection group, cooling or insulation type, loss data, impedance, and installation environment, quantity, destination, and the expected delivery schedule. The engineering review will be based on the selected amorphous alloy transformer and project drawing.
ORDERING INSTRUCTIONS
- State the required SH15-M configuration, quantity, project destination, and intended application.
- Provide capacity, voltage combination, tap range, connection group, impedance, loss data, cooling or insulation type, and installation environment for technical review.
- Confirm confirm the capacity-specific outline dimensions, installation base, terminal position, cooling clearance, and lifting / handling requirements before final production or installation planning.
- List any special environmental, wiring, communication, metering, protection, or component requirements in the inquiry.
Technical Support & Documentation
Series Technical DocumentRequest the series technical document for amorphous alloy transformer supplier and compare SH15-M with related models and confirmed technical data.Project Technical SupportSend project data for sealed amorphous alloy transformer manufacturer so CANGO can review rated values, configuration notes, and application conditions.Send Single Line DiagramShare the single-line diagram or layout when checking outdoor amorphous core transformer factory for the selected SH15-Mconfiguration.Engineering ConsultationDiscuss site conditions, documentation needs, and quotation details for low loss amorphous power transformer exporter.
FAQ
Related Products
SZ11 10kV and 35kV On-Load Tap-Changing TransformerSZ11 10kV and 35kV On-Load Tap-Changing Transformer for urban and rural power grids.SC(B)10 Dry-Type Power TransformerSC(B)10 Dry-Type Power Transformer for commercial and industrial electrical projects.SC(B)12 Dry-Type Power TransformerSC(B)12 Dry-Type Power Transformer for commercial and industrial electrical projects.SC(B)13 Dry-Type Power TransformerSC(B)13 Dry-Type Power Transformer for commercial and industrial electrical projects.
Contact / Inquiry CTA
Send project data for SH15-M. The fields below are the recommended information for quotation and technical review.
Use the buttons below to send the project request by email or open the contact page. If you have drawings, attach the file in the email or share a file link in the message.
Request Quotation for SH15-M
This is project-based power distribution equipment. Share the single-line diagram, rated data, cabinet arrangement, quantity, and destination, and CANGO will review the configuration before quotation.