Subscribe to our Newsletter
Model No: S22-M-NX1
S22-M-NX1 Oil-Immersed Distribution Transformer | CANGO
CANGO supplies S22-M-NX1 Level 1 energy-efficiency oil-immersed transformers for utility distribution networks. Send rated data, drawings, quantity and destination.
Quantity :
CANGO Product Detail
S22-M-NX1 Oil-Immersed Distribution Transformer | CANGO
Power Transformers for B2B Electrical Projects
S22-M-NX1 Level 1 Energy-Efficiency Oil-Immersed Transformer is supplied for utility distribution networks. CANGO reviews rated data, drawings, quantity, destination, and configuration notes before quotation.
Model
S22-M-NX1
Category
Power Transformers
Application
Utility distribution networks
Supply Type
Project quotation and technical support
Product Overview
S22-M-NX1 oil-immersed transformer is identified in the technical document as a level 1 energy-efficiency transformer. It is commonly used for utility distribution networks and industrial distribution systems, with the final selection based on rated data, drawings, and site conditions.
utilities, EPC contractors, transformer distributors, industrial project owners, and electrical engineering companies can request configuration review for level 1 oil immersed transformer. Please send capacity, voltage combination, tap range, connection group, cooling or insulation type, loss data, impedance, and installation environment, quantity, destination, and any project standard requirements for quotation.
Model and Meaning

Key Features
01
Capacity Selection
S22-M-NX1: Capacity, high-voltage and low-voltage combination, tap range, and connection group are confirmed before quotation. This point is especially relevant to level 1 oil immersed transformer.
02
Cooling and Insulation
Oil-immersed, dry-type, amorphous alloy, and H-class requirements are reviewed according to installation conditions. For S22-M-NX1, check this together with the selected project scheme.
03
Loss Data Review
No-load loss, load loss, impedance, and efficiency-related data should be matched with the selected capacity. On S22-M-NX1, confirm the application duty, site layout, and project standard before selection.
04
Project Installation
Foundation, lifting, terminal position, ventilation, and clearance requirements need confirmation before delivery. Use the S22-M-NX1 drawings and rated data to confirm this point before quotation.
05
Application Flexibility
Transformer selection can support utility, industrial, commercial, indoor, outdoor, and renewable-energy projects. For S22-M-NX1, review this with level 1 oil immersed transformer and the final installation plan.
Technical Specifications
Main Performance Parameters of S22-M-NX1 10 kV Level 1 Oil-Immersed Transformer
| Model | Rated capacity (kVA) | Connection group | High voltage (kV) | Tap range (%) | Low voltage (kV) | No-load loss (W) | Dy load loss (W) | Yy load loss (W) | No-load current (%) | Short-circuit impedance (%) |
|---|---|---|---|---|---|---|---|---|---|---|
| S22-M-30/10-NX1 | 30 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 65 | 455 | 430 | 1.5 | 4 |
| S22-M-50/10-NX1 | 50 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 80 | 655 | 625 | 1.3 | 4 |
| S22-M-63/10-NX1 | 63 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 90 | 785 | 745 | 1.2 | 4 |
| S22-M-80/10-NX1 | 80 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 105 | 945 | 900 | 1.2 | 4 |
| S22-M-100/10-NX1 | 100 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 120 | 1140 | 1080 | 1.1 | 4 |
| S22-M-125/10-NX1 | 125 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 135 | 1360 | 1295 | 1.1 | 4 |
| S22-M-160/10-NX1 | 160 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 160 | 1665 | 1585 | 1 | 4 |
| S22-M-200/10-NX1 | 200 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 190 | 1970 | 1870 | 1 | 4 |
| S22-M-250/10-NX1 | 250 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 230 | 2300 | 2195 | 0.9 | 4 |
| S22-M-315/10-NX1 | 315 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 270 | 2760 | 2630 | 0.9 | 4 |
| S22-M-400/10-NX1 | 400 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 330 | 3250 | 3095 | 0.8 | 4 |
| S22-M-500/10-NX1 | 500 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 385 | 3900 | 3710 | 0.8 | 4 |
| S22-M-630/10-NX1 | 630 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 460 | 4460 | 4460 | 0.6 | 4.5 |
| S22-M-800/10-NX1 | 800 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 560 | 5400 | 5400 | 0.6 | 4.5 |
| S22-M-1000/10-NX1 | 1000 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 665 | 7415 | 7415 | 0.6 | 4.5 |
| S22-M-1250/10-NX1 | 1250 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 780 | 8640 | 8640 | 0.5 | 4.5 |
| S22-M-1600/10-NX1 | 1600 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 940 | 10440 | 10440 | 0.5 | 4.5 |
| S22-M-2000/10-NX1 | 2000 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 1085 | 13180 | 13180 | 0.4 | 5 |
| S22-M-2500/10-NX1 | 2500 | Yyn0 or Dyn11 | 10.5 / 10 / 6.3 / 6 | +/-5% / +/-2 x 2.5% | 0.4 | 1280 | 13360 | 13360 | 0.4 | 5 |
Installation Dimensions / Drawing
ForS22-M-NX1, confirm the capacity-specific outline dimensions, installation base, terminal position, cooling clearance, and lifting / handling requirements. Use the confirmed technical table, project drawing, and site installation plan as the final dimensional reference before ordering or installation.
Applications
S22-M-NX1 is mainly selected for utility distribution networks and industrial distribution systems. The final application should match the confirmed level 1 oil immersed transformer, rated data, and site installation conditions.
- Utility distribution networks
- Industrial distribution systems
- Projects requiring level 1 energy-efficiency transformer options
Customization Options
Cooling Method
Oil-immersed, dry-type, natural cooling, forced-air, or special cooling requirements should be confirmed by model and site condition. Apply this review to S22-M-NX1 and its level 1 oil immersed transformer.
Winding Material
Copper or aluminum winding requirements should be confirmed when the project specification requires a fixed material. Apply this review to S22-M-NX1 and its level 1 oil immersed transformer.
Loss Data
No-load loss, load loss, impedance voltage, and efficiency information should be checked against the selected capacity. Apply this review to S22-M-NX1 and its level 1 oil immersed transformer.
Installation Method
Indoor, outdoor, foundation, ventilation, lifting, terminal position, and clearance requirements should be provided before quotation. Apply this review to S22-M-NX1 and its level 1 oil immersed transformer.
Cooling Method and Winding Material
Cooling Review
Confirm oil-immersed, dry-type, natural cooling, forced-air, or other cooling requirements according to the installation site. Apply this review to S22-M-NX1 and its level 1 oil immersed transformer.
Winding Requirement
State copper or aluminum winding requirements when the project specification defines the material. Apply this review to S22-M-NX1 and its level 1 oil immersed transformer.
Loss Data and Efficiency Information
Performance Data
No-load loss, load loss, impedance, noise, and temperature rise should be reviewed for the selected capacity. Apply this review to S22-M-NX1 and its level 1 oil immersed transformer.
Efficiency Review
Energy-efficiency level or local efficiency requirements should be confirmed before quotation if required by the project. Apply this review to S22-M-NX1 and its level 1 oil immersed transformer.
Ordering Instructions / Information Required for Quotation
ForS22-M-NX1, send capacity, voltage combination, tap range, connection group, cooling or insulation type, loss data, impedance, and installation environment, quantity, destination, and the expected delivery schedule. The engineering review will be based on the selected level 1 oil immersed transformer and project drawing.
ORDERING INSTRUCTIONS
- State the required S22-M-NX1 configuration, quantity, project destination, and intended application.
- Provide capacity, voltage combination, tap range, connection group, impedance, loss data, cooling or insulation type, and installation environment for technical review.
- Confirm confirm the capacity-specific outline dimensions, installation base, terminal position, cooling clearance, and lifting / handling requirements before final production or installation planning.
- List any special environmental, wiring, communication, metering, protection, or component requirements in the inquiry.
Technical Support & Documentation
Series Technical DocumentRequest the series technical document for level 1 oil immersed transformer supplier and compare S22-M-NX1 with related models and confirmed technical data.Project Technical SupportSend project data for high efficiency oil immersed transformer manufacturer so CANGO can review rated values, configuration notes, and application conditions.Send Single Line DiagramShare the single-line diagram or layout when checking 10kv level 1 distribution transformer factory for the selected S22-M-NX1configuration.Engineering ConsultationDiscuss site conditions, documentation needs, and quotation details for level 1 distribution transformer exporter.
FAQ
Related Products
35kV Series Distribution Transformer35kV Series Distribution Transformer for 35 kv distribution projects.SH15-M Sealed Amorphous Alloy Power TransformerSH15-M Sealed Amorphous Alloy Power Transformer for outdoor power distribution systems.SZ11 10kV and 35kV On-Load Tap-Changing TransformerSZ11 10kV and 35kV On-Load Tap-Changing Transformer for urban and rural power grids.SC(B)10 Dry-Type Power TransformerSC(B)10 Dry-Type Power Transformer for commercial and industrial electrical projects.
Contact / Inquiry CTA
Send project data for S22-M-NX1. The fields below are the recommended information for quotation and technical review.
Use the buttons below to send the project request by email or open the contact page. If you have drawings, attach the file in the email or share a file link in the message.
Request Quotation for S22-M-NX1
This is project-based power distribution equipment. Share the single-line diagram, rated data, cabinet arrangement, quantity, and destination, and CANGO will review the configuration before quotation.